What Electrical Conductivity Actually Tells You
Electrical conductivity is not a measure of nutrition; it is a measure of total dissolved ions. Two solutions with the same reading can differ completely in composition, one rich in potassium and calcium, the other loaded with sodium and chloride. Reading electrical conductivity as if it were a nutritional score is the most common mistake in fertigation management.
Practical targets for fruiting crops usually start near 1.5 to 2.0 for young transplants, rise through vegetative growth to roughly 2.0 to 2.5, and reach 2.5 to 3.5 during heavy fruit fill, depending on light levels and water quality. These are starting points, not fixed setpoints. A salt-sensitive variety, saline source water, or unusually high radiation shifts every target downward or upward.

pH and the Availability Window
pH governs whether nutrients can be absorbed at all. In hydroponic solution, the workable range sits around 5.5 to 6.2, with slightly wider tolerance in substrate culture. Above neutral, phosphorus, iron, manganese and boron become progressively unavailable even when they are present in adequate quantity.
Solutions have very little buffering capacity, so pH drifts whenever the crop absorbs ions selectively. Tomatoes take up more anions than cations during fruit fill, which pushes pH upward; ammonium nutrition pushes it down. A dosing controller that measures and corrects continuously, rather than on a weekly visit, is the practical answer.
Water Quality Before Recipe
No recipe survives bad water. Source alkalinity, sodium, chloride, and iron content determine what the nutrient formula must compensate for. Water with high bicarbonate content requires acid injection before fertilizer is added, otherwise the pH will not hold in the root zone.
Laboratory analysis of source water once or twice a year, plus regular in-house checks of electrical conductivity and pH, forms the baseline. In coastal or arid regions, sodium accumulation in recirculating systems becomes the limiting factor long before nutrient balance does, and must be managed by controlled discharge rather than by wishful thinking.

Reading Drain and Substrate
The solution you mix is not the solution the roots receive. Substrate extracts ion, water is transpired, and electrical conductivity rises in the slab. Measuring drain electrical conductivity and pH, and comparing them with the input, reveals what is actually happening at root level.
A common target is drain electrical conductivity one to one and a half units above input during fruit load, with substrate moisture held in a stable band. When drain conductivity climbs faster than expected, either irrigation volume is too low or the substrate is accumulating salts and needs a controlled flush.
Correcting Drift Without Overcorrecting
Fertigation errors compound because corrections are usually applied to the whole tank. A single oversized acid dose can shift pH for a full day; an over-concentrated batch can shock roots within hours. Change one variable at a time, in small increments, and measure the result before the next change.
Recipe management should be written down. Each crop stage has a target recipe, a target electrical conductivity, and a target pH, with recorded adjustments and the reason for each. That record becomes the operating manual for the next crop, and it prevents the slow drift that turns a good recipe into a mediocre one over several seasons.
Recorded history is the most underused asset in fertigation. Most operations hold several seasons of tank readings, drain analyses, and harvest weights without ever comparing them. Plotting electrical conductivity against yield by crop and season reveals the range where the system performs best on that site, and that range is worth more than any generic recommendation in a handbook.
Automation has changed what is realistic in solution management, but it has not removed the need for judgement. A dosing computer can hold pH within a tenth of a unit and maintain conductivity to a target, yet it cannot decide whether that target is right for the light level and fruit load on a particular afternoon. Growers still have to interpret the season, and the controller simply executes the decision reliably.
Conclusion
Nutrient management is measurement plus discipline, not a proprietary formula. Set targets by stage, verify against drain readings, and correct in small steps. Shouguang Zhongtian supplies fertigation systems with dosing control, drain monitoring, and recipe management so that electrical conductivity and pH stay inside the window the crop actually needs.